BPJSV - HOT ROLLED PLATES

  • MSDS: BPJSV
  • Manufacturer: GARY STEEL CO
  • Product Name: HOT ROLLED PLATES
  • National Stock Number: 9540-00N031003
Product Identification

Product ID:HOT ROLLED PLATES
MSDS Date:04/15/1986
FSC:9540
NIIN:00N031003
MSDS Number: BPJSV

Responsible Party
GARY STEEL CO
2560 7TH ST
BERKELEY, CA 94710-2438
US

Emergency Phone: 213-549-3000;213-775-7501

Info Phone: 415-644-0900

Cage: 8Y889

Contractor
GARY STEEL CO
BERKELEY, CA 94710-2438 US

Telephone: 415-644-0900

Cage: 8Y889

Ingredients

0.01-1.25

CAS: 7440-47-3

RTECS: GB4200000

Fraction By Weight: INGRED

OSHA PEL 1 MG/M3

ACGIH TLV: 0.5 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


0.01-0.1

CAS: 7439-98-7

RTECS: QA4680000

Fraction By Weight: INGRED

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3; 9293


0.01-0.15

CAS: 7440-62-2

RTECS: YW1355000

Fraction By Weight: INGRED

OSHA PEL C,0.5 MG V2O5/M3 RD

ACGIH TLV: 0.05 MG V205/M3;9293


0.01-0.7

CAS: 7440-50-8

RTECS: GL5325000

Fraction By Weight: INGRED

OSHA PEL 0.2 MG/M3 FUME 1DUST

ACGIH TLV: 0.2 MG/M3 FUME 1DUST

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


0.01-0.08

CAS: 7440-03-1

Fraction By Weight: INGRED


ALUMINUM

CAS: 7429-90-5

RTECS: BD0330000

Fraction By Weight: 0.10%MAX

OSHA PEL 15MG/M3 DUST;5 FUME

ACGIH TLV: 10MG/M3 DUST


HEXAVALENT CHROMIUM HAS BEEN RELATED TO AN

RTECS: 9999999ZZ


2750F.

RTECS: 9999999ZZ

Fraction By Weight: 95-99%


IRON

CAS: 7439-89-6

RTECS: NO4565500

OSHA PEL 10 MG/M3 (FE)

ACGIH TLV: 5 MG/M3(FE)


ALLOYING ELEMENTS CONSISTING OF INGREDIENTS 4-15

RTECS: 9999999ZZ


0.01-0.35

CAS: 7440-44-0

RTECS: FF5250100

Fraction By Weight: INGRED

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293


0.25-1.65

CAS: 7439-96-5

RTECS: OO9275000

Fraction By Weight: INGRED

OSHA PEL (C) 5 MG/M3 DUST

ACGIH TLV: 5 MG/M3 DUST 9293


0.001-0.15

CAS: 7723-14-0

RTECS: TH3495000

Fraction By Weight: INGRED

OSHA PEL 0.01 MG/M3

ACGIH TLV: 0.01 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


SULFUR

CAS: 7704-34-9

RTECS: WS4250000

Fraction By Weight: 0.05%MAX

OSHA PEL 2 PPM (SO*2)

ACGIH TLV: 2 PPM (SO*2)


0.01-0.75

CAS: 7440-21-3

RTECS: VW0400000

Fraction By Weight: INGRED

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


0.01-0.65

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: INGRED

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHRONIC INHAL OF HIGH CONC OF IRON
OXIDE FUMES/DUSTS MAY LEAD TO A BENIGN PNEUMOCONIOSIS (SIDEROSIS).
INHAL OF HIGH CONC OF FERRIC OXIDE MAY POSSIBLY ENHANCE RISKS OF
LUNG CANCER DEVEL IN WORKERS EXPO S TO PULM CARCIN. INHAL OF HIGH
CONC OFFRESHLY FORMED OXIDE FUMES & DUSTS OF MANGANESE, COPPER,
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: LEAD &/OR ZINC IN RESPIRABLE PARTICLE
SIZE RANGE CAN CAUSE AN INFLUENZA-LIKE ILLNESS TERMED METAL FUME
FEVER. TYPICAL SYMP LAST 12-48 HRS & ARE CHARACT BY METALLIC TASTE
IN MOUTH, DRYNESS & IRRIT OF THROAT, FOLLOWED BY WEAK, MUSCLE
PAIN, FEVER & CHILLS. EXPOS TO HIGH CONC OF NICKEL DUSTS & FUMES
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF BREATHING IS DIFFICULT OR HAS
STOPPED, ADMINISTER ARTF RESP/O2 AS INDICATED. SEEK MED ATTN
PROMPTLY. TREAT METAL FUME FEVER BY BED REST, & ADMINISTER PAIN &
FEVER REDUCI NG MEDICATION. INGEST: CALL MD IMMED . EYES: IMMED
FLUSH WITH POTABLE WATER FOR A MINIMUM OF 15 MIN, SEEK ASSISTANCE
FROM MD . SKIN: FLUSH WITH COPIOUS AMOUNTS OF WATER. CALL MD .

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:STEEL PRODUCTS IN THE SOLID STATE PRESENT
NO FIRE OR EXPLOSION HAZARD.

Accidental Release

Spill Release Procedures:NOT APPLICABLE TO STEEL IN SOLID STATE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:OPERATIONS W/POTNTL FOR GENERATING
HIGH CONC OF AIRBORNE PARTICULATES SHOULD BE EVALUATED & CONTROLLED
AS NEC. AVOID BRTHG METAL FUMES &/OR DUSTS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPRVD DUST & FUME RESP SHOULD BE
USED TO AVOID EXCESS INHAL OF PARTICULATES. APPROP RESP SELECTION
DEPENDS ON MAGNITUDE OF EXPOSURE.
Ventilation:LOC EXHAUST VENT SHOULD BE PROVIDED WHEN WELD, BURN, SAW,
BRAZ,GRIND OR MACHINING TO PVNT EXCESSIVE DUST/FUME EXPOS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:DPNDG UPON CNDTNS OF USE & SPEC WORK
SITUATONS, ADDNL PROT EQUIP &/OR CLTHG MAY BE REQD TO CONTROL
EXPOSURES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
EFTS OF OVEREXP: CAN CAUSE SENSIT DERM, RESP IRRIT, ASTHMA, PULM
FIBROSIS & EDEMA. CERTAIN FORMS OF NICKEL DUST MAY CAUSE NASAL/LUNG
CANCER IN HUMANS. RPTD/PRLNG EXPOS TO HEXAVALENT CHROMIUM CMPDS MAY
CAUSE RESP IRRIT, NOSEBLEED, ULCERATION & PERFORATION OF NASAL
SEPTUM. INDUST EXPOS TO CERTAIN FORMS OF (ING 16)

Chemical Properties

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:ING 1
Appearance and Odor:METALLIC GRAY, NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
WILL REACT WITH STRONG ACID TO LIBERATE HYDROGEN.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:@ TEMP ABOVE MP, MAY LIBERATE FUMES
CONTAINING OXIDES OF IRON AND ALLOYING ELEMENTS.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.